  1. Newsgroups: comp.dcom.modems
  2. Path: ncrgw2.ncr.com!ncrhub6!daynews!ranger!news
  3. From: Jim Dell <72037.772@compuserve.com>
  4. Subject: Sportster 33.6 disconnect problem
  5. X-Nntp-Posting-Host: 192.127.247.27
  6. Message-ID: <DKo1sF.EDv@ranger.daytonoh.attgis.com>
  7. Sender: news@ranger.daytonoh.attgis.com (News Administrative Login)
  8. Reply-To: 72037.772@compuserve.com (dellji)
  9. Organization: Home Computer
  10. X-Newsreader: DiscussIT 2.5.1.3 for MS Windows [AT&T Software Products Division]
  11. Date: Thu, 4 Jan 1996 16:57:51 GMT
  12.  
  13. I am  having problems with a brand new U.S. Robotics Sportster 28.8  and 
  14. Windows 95Æs dial-up networking.  After connecting and surfing
  15. the net for a 
  16. short while it disconnects.
  17.  
  18. Vitals:
  19. External Sportster modem 28.8 
  20. 486/66 8MB
  21. 16550 Serial ports with FIFO enabled via Windows 95
  22. Modem installed with new INF file from USR
  23. Modem firmware dates are EPROM 10/18/95 
  24.                          DSP 10/18/95
  25. EPROM rev 1.1
  26. DSP rev  1.1      
  27.  
  28. I think the ISP is using AT&T Comsphere modems
  29.  
  30. System works perfectly with the previous modem an AT&T Dataport 14.4.
  31.  
  32. HereÆs the results from the Sportster ATI6 command using the tip
  33. from John 
  34. Navas' FAQ to get the results in Windows 95 Dial-up networking.
  35. One clarification on John's tip - when you get the "Reconnection Message"
  36. leave it on your screen and run Hyperterminal to get the ATI6 results.
  37.  
  38. USRobotics Sportster 33600 Fax Link Diagnostics...
  39.  
  40. Chars sent                18771      Chars Received           617561
  41. Chars lost                    0
  42. Octets sent               11339      Octets Received          250418
  43. Blocks sent                1009      Blocks Received            4848
  44. Blocks resent                 0
  45.  
  46. Retrains Requested            0      Retrains Granted              0
  47. Line Reversals                0      Blers                         1
  48. Link Timeouts                 0      Link Naks                     0
  49.  
  50. Data Compression       V42BIS 2048/32
  51. Equalization           Long
  52. Fallback               Disabled
  53. Protocol               LAPM
  54. Speed                  26400/24000
  55. Last Call              00:04:15
  56.  
  57. Disconnect Reason is a Rootless Tree
  58.  
  59. OK
  60.  
  61. 12/30/95 15:51
  62.  
  63. Things I have tried:
  64.  
  65. My test consists of entering the following into NetscapeÆs URL line
  66.  
  67. ftp://ftp.usr.com/sys/pcb/pcbfiles.lst
  68.  
  69. If the file (900KB+) downloads okay, I consider the system working okay.
  70. Here's the results of some of my testing.  Using the PPPLOG.TXT and 
  71. MODEMLOG.TXT files to verify certain items.
  72.  
  73. Init String  Additional Settings  Compress   Error  Control  Results
  74. Default      S10=100 S15=8         on        on       Remote Hung up
  75. Default      S10=100 S15=64        on        on       Had to turn modem
  76.                                                       off also had
  77.                                                       CRC errors
  78. Default     S10=100 &K3 S15=128    off       off      Hung up okay 
  79.                                                       connected at 57,600
  80.                                                       but had 52 CRCs
  81. Default     &C0                    off       on       Seemed to
  82. work okay but
  83.                                                       log shows
  84. modem wouldn't
  85.                                                       hang up
  86. Default     S10=100                on        on       Remote
  87. modem hung up
  88. Default     &F1                    on        on       Didn't work. Had to
  89.                                                       manually
  90. turn modem off.
  91.                                                       Netscape & Mosiac
  92.                                                       stopped responding.
  93. Default     none                   on        on       Remote
  94. modem hung up and
  95.                                                      ATI6 gave
  96. "Rootless Tree"
  97.                                                      as
  98. disconnect reason.
  99.  
  100.  
  101. Also Compuserve WINCIM 2.01 using local access number (513) 224-4576 and 
  102. default settings will disconnect on file downloads.  Going into WINCIM's
  103. settings and clicking off "Error Control" and "Compression" permits me
  104. to stay connect.
  105.  
  106. Any help to get this Sportster performing at top speed would be
  107. appreciated.
  108.  
  109. Jim